Influência do tamanho do voxel na acurácia de medidas lineares obtidas em imagens de TCFC

Autores

  • Raiza Meira Vieira Discipline of Oral Radiology, Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, SP
  • Karina Cecília Panelli Santos Discipline of Oral Radiology, Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, SP
  • Denise Sabbagh Haddad Discipline of Oral Radiology, Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, SP
  • Claudio Costa Discipline of Oral Radiology, Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, SP
  • Jefferson Xavier Oliveira Discipline of Oral Radiology, Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, SP

DOI:

https://doi.org/10.11606/issn.2357-8041.clrd.2014.81730

Palavras-chave:

Radiologia, Tomografi a Computadorizada de Feixe Cônico, Voxel.

Resumo

Objetivo: A tomografia computadorizada de feixe cônico (TCFC) introduziu uma inovação nos métodos de exame por imagem e tem apresentado grande potencial na área maxilofacial. O objetivo deste estudo foi avaliar a influência de diferentes resoluções (voxels) sobre medidas lineares obtidas utilizando-se a TCFC. Método: Foram utilizadas 7 mandíbulas suínas neste estudo. Foram obtidas medidas da distância mésio-distal dos primeiros molares direito e esquerdo. As mandíbulas suínas foram escaneadas num aparelho iCAT com voxel de 0,125 e 0,25 mm. As imagens obtidas foram visualizadas no software Xoran CT, e as medidas lineares foram realizadas por dois examinadores em tempos distintos com o auxílio da régua eletrônica do software. Os mesmos utilizaram um paquímetro digital para a medição realizada nas peças anatômicas. Os dados foram submetidos à avaliação estatística. Resultados: Os resultados apontam não haver diferença estatisticamente significativa entre as medidas obtidas por ambos os avaliadores. Com relação aos métodos empregados, não se observou diferença estatisticamente significativa entre as medidas obtidas com o paquímetro digital e com a TCFC. Da mesma forma, não se observou diferença significativa entre as medidas obtidas utilizando-se os diferentes protocolos de TCFC. Conclusão: Não há diferença significativa entre medidas lineares de imagens de TCFC obtidas com tamanho de voxel de 0,125 e 0,25 mm.

Downloads

Os dados de download ainda não estão disponíveis.

Biografia do Autor

  • Karina Cecília Panelli Santos, Discipline of Oral Radiology, Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, SP
    Departamento de Estomatologia

Referências

Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom).Dentomaxillofac Radiol. 2004 Sep;33(5):291-4.

Ludlow JB, Laster WS, See M, Bailey LJ, Hershey HG.Accuracy of me-asurements of mandibular anatomy in cone beam computed tomography images.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007 Apr;103(4):534-42.

Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y.Accuracy of linear me-asurements from cone-beam computed tomography-derived surface mo-dels of different voxel sizes.Am J Orthod Dentofacial Orthop. 2010 Jan;137(1):16.e1-6

Suomalainen A, Vehmas T, Kortesniemi M, Robinson S, Peltola J.Accuracy of linear measurements using dental cone beam and conven-tional multislice computed tomography.Dentomaxillofac Radiol. 2008 Jan;37(1):10-7.

Spin-Neto R, Gotfredsen E, Wenzel A. Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review. J Digit Imaging. 2013 Aug;26(4):813-20

Oltramari P.V., Navarro R.L., .Hentiques J.F.,Capelozza A.L., Granjeiro J.M. Dental and skeletal characterization of the BR-1 minipig; Vet J. (2007) 173(2): 399-407

Wang S, Liu Y, Fang D, Shi S. The miniature pig: a useful large animal model for dental and orofacial research. Oral Dis 2007; Nov;13(6):530-7

Torres MG, Campos PS, Segundo NP, Navarro M, Crusoé-Rebello I.Accuracy of linear measurements in cone beam computed tomography with different voxel sizes.Implant Dent. 2012 Apr;21(2):150-5.

Patcas R, Müller L, Ullrich O, Peltomäki T.Accuracy of cone-beam com-puted tomography at different resolutions assessed on the bony covering of the mandibular anterior teeth.Am J Orthod Dentofacial Orthop. 2012 Jan;141(1):41-50.

Downloads

Publicado

2014-12-31

Edição

Seção

Artigos originais