Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment

Authors

  • Ligia Buloto Schmitd University of São Paulo; Bauru School of Dentistry; Department of Stomatology
  • Tatiana de Castro Lima University of São Paulo; Bauru School of Dentistry
  • Luiz Eduardo Montenegro Chinellato University of São Paulo; Bauru School of Dentistry; Department of Stomatology
  • Clóvis Monteiro Bramante University of São Paulo; Bauru School of Dentistry; Department of Operative Dentistry, Endodontics and Dental Materials
  • Roberto Brandão Garcia University of São Paulo; Bauru School of Dentistry; Department of Operative Dentistry, Endodontics and Dental Materials
  • Ivaldo Gomes de Moraes University of São Paulo; Bauru School of Dentistry; Department of Operative Dentistry, Endodontics and Dental Materials
  • Norberti Bernardineli University of São Paulo; Bauru School of Dentistry; Department of Operative Dentistry, Endodontics and Dental Materials

DOI:

https://doi.org/10.1590/S1678-77572008000200016

Keywords:

Radiography, Photostimulated phosphor plate system, Digora

Abstract

The aims of this study were to evaluate the quality of indirect digitized radiographic images taken during endodontic procedures and to compare the measurements recorded with this technique to those obtained from conventional radiographs. Two-hundred conventional periapical radiographs taken at the undergraduate Endodontics Clinic of the Dental School of Bauru were digitized. The conventional and indirect digitized images were compared by three examiners as to the quality and accuracy of the measurements recorded during endodontic treatment, in canal length determination, gutta-percha adaptation, lateral condensation and final obturation. The conventional radiographs were observed on a film viewer, surrounded by a dark card, and measured with magnifying glass and a millimeter ruler; the indirect digitized images were evaluated on the Digora® for Windows software, with free utilization of the bright/contrast tool. Unlike the conventional radiographic images, all indirect digitized images were considered as having a high quality. The distance between the filling material and the root apex was 0.117 mm larger, on average, for the Digora® system (p<0.01). The measurements achieved by the investigated radiographic methods were clinically similar and they are thus equivalent. Changes in brightness and contrast of the images using Digora®software improved the diagnosis.

Downloads

Download data is not yet available.

Downloads

Published

2008-04-01

Issue

Section

Original Articles

How to Cite

Comparison of radiographic measurements obtained with conventional an indirect digital imaging during endontic treatment . (2008). Journal of Applied Oral Science, 16(2), 167-170. https://doi.org/10.1590/S1678-77572008000200016